Enerdrive ePOWER 2000W 12V True Sine Wave Inverter with AC Transfer & Safety Switch

SKU: EN1120S-X
Regular price $1,544.00 inc GST

Features

ePOWER 2000W True Sine Wave Inverter with AC Transfer Switch & Safety Switch

The ePOWER 2000W Inverter with AC Transfer & Safety Switch is one in a family of affordable, high quality, professional level inverters by Enerdrive. By using the latest power conversion technology, ePOWER inverters deliver clean and energy efficient true sine wave AC power from your DC supply.

This ePOWER Inverter incorporates a 16A AC Transfer Switch which allows for seamless AC power transfer between Mains/Generator and Inverter. This helps to keep your appliances running with almost no break time on AC transfer and allows for a much simpler installation on-board.

Also included in the unit is a RCD Safety Switch. This switch monitors the flow of electricity through the inverter and detects any problems that may pose a risk to personal safety and switches the output power off within 0.03 of a second.

The ePOWER 2000W is built to operate basic equipment such as power tools, computers, microwave ovens, televisions and other appliances that use up to 2000W of power for operation. All Enerdrive ePOWER Inverters are covered by our extensive 5 Year warranty.

ePOWER Inverter Features:

  • Seamless 16A AC Internal Transfer Switch
  • AC RCD/Safety Switch with test button
  • Removable LED Remote Control Display Panel
  • Regulated Pure Sine Wave Output
  • Silent Operation
  • Compact Size for Easy Installation
  • USB Port for charging USB devices
  • Specifications

    Model – Description EN1120S-X EN1120S-X-24v EN1226S-X
    AC Output Power 2000W 2000W 2600W
    AC Output Current 8.7A 8.7A 11.3A
    AC Output Voltage 230 Vac / 50 Hz
    AC Output Waveform Sinewave (<3% THD)
    Nominal DC Input Voltage 12.5 VDC 24.5 VDC 12.5 VDC
    No Load battery draw < 1.5 ADC
    DC Input Voltage operating range 10.5 – 15.5 VDC 21.0 – 31.0 VDC 10.5 – 15.5 VDC
    Under Voltage Alarm 11.0 / 12.1 VDC 22.0 / 24.2 VDC 11.0 / 12.1 VDC
    Under Voltage Alarm Recovery 11.3 / 12.3 VDC 22.6 / 24.6 VDC 11.3 / 12.3 VDC
    Under Voltage Shutdown 10.5 / 11.8 VDC 21.0 / 23.6 VDC 10.5 / 11.8 VDC
    Under Voltage Shutdown Recovery 12.0 / 12.6 VDC 24.0 / 25.2 VDC 12.0 / 12.6 VDC
    Over Voltage Shutdown 15.5 VDC 31.0 VDC 15.5 VDC
    USB Port 5V, 2.1A
    AC Transfer Switch
    Transfer Time < 30 ms
    Transfer Relay Rating 16A (resistive load)
    AC Input socket IEC-C20 16A max
    AC Output socket IEC-C19 16A max
    AC Output Front GPO 10A max
    Safety and Environmental
    Conformance All required Australian Standards , CE LVD: EN/IEC 62040-1, IEC61558-2-16
    EMI / EMC CE EMC: EN/IEC 62040-2 category C1
    Agency Markings RCM , CE
    Operating Temperature 0°C to 40°C
    Storage Temperature -20°C to 60°C
    Relative Humidity 5-90% non-condensing
    Operating Altitude Up to 3000 meters above sea level
    Weights and Dimensions
    Weight 5.9 kg 5.9 kg 7.0 kg
    Dimensions (W x L x H) 444x230x115 mm 444x230x115 mm 560x230x115 mm
    Warranty 5 Years

    Note: Specifications subject to change without notice.

    Estimate Run Time On Load

    Following run times are estimates for reference, based on using different battery bank sizes. Actual run times may vary.

    Important: Power Drain from DC Battery Bank.

    Please note that there is a power drain of approx 700mA from the battery bank when the Inverter is running in AC By-Pass mode. In order to avoid draining down the battery bank, a battery charger with sufficient power is required to maintain the battery bank voltage.

    Estimate run time on different 12V Battery Bank Size
    AC Load 60AH 120AH 180AH 240AH 300AH
    50 W 11 hrs 22 hrs 33 hrs 44 hrs 55 hrs
    100 W 5 hrs 11.5 hrs 17 hrs 23 hrs 29 hrs
    200 W 2.5 hrs 5 hrs 8 hrs 11 hrs 13.5 hrs
    500 W 49 mins 2 hrs 3 hrs 4 hrs 5 hrs
    1000 W 15 mins 49 mins 1.5 hrs 2 hrs 2.5 hrs
    1500 W 8 mins 27 mins 49 mins 1 hrs 1.5 hrs
    2000 W N.R. 15 min 34 mins 49 mins 1 hrs
    2600 W N.R. 11 min 25mins 37 mins 49 mins